Nx 8 Manual
NX-8 Control 20 DEFAULT ZONE TYPES (Configurations) Zones can be programmed to be one of twenty different zone types (configurations). Zone types # 17 - 20 can be used for wireless or hardwired zones using European double EOL configuration. The default zone types are listed below. These zone types can be customized by programming locations 110-149. DATA DESCRIPTION OF DEFAULT ZONE TYPES '1' DAY ZONE - Instant when system is armed trouble zone when system is disarmed. '2' 24-HOUR AUDIBLE - Creates an instant yelping siren alarm regardless of the armed state of the control panel.
Nx-148e-cf 4 this manual is furnished to help you understand your security system and become proficient in its operation. All users of your security system should read and follow the instructions and.
'3' ENTRY/EXIT DELAY 1- A trip will start entry delay 1. The lack of a trip during exit delay will enable the Automatic Bypass or Instant mode if so programmed. '4' FOLLOWER WITH AUTO- BYPASS DISABLED - This zone will be instant when the system is armed and no entry or exit delays are being timed. It is delayed during entry and exit delay times. This zone will not automatically bypass even if enabled in Segment 1 of Location 23. '5' INTERIOR FOLLOWER WITH AUTO- BYPASS ENABLED - This zone will be instant when the system is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times.
King kt76a mode c transponder. Applicable Documents: TSO C74b, RTCA DO-138, DAPBBBXXXXXX Class I Temperature Range: -15 to +55C for continuous operation Transmitter Frequency: 1090 MHz +-3 MHz Receiver Frequency: 1030 MHz (crystal controlled local oscillator Receiver Sensitivity: -74dBm (nominal); -72dBm (min.
This zone will automatically bypass if enabled in Segment 1 of Location 23. '6' INSTANT - This zone creates an instant alarm whenever it is tripped and the Armed LED is on. '7' 24-HOUR SILENT - Creates an instant silent alarm regardless of the armed state of the control panel. It will not display on the keypad. '8' FIRE - This zone will light the Fire LED and sound the temporal siren each time the zone is shorted. It will also rapidly flash the Fire LED indicating a trouble if the zone is open.
'9' ENTRY/EXIT DELAY 2- A trip will start entry delay 2. The lack of a trip during exit delay will enable the Automatic Bypass or Instant mode if so programmed.
'10' 24-HOUR SILENT SUPERVISED- Creates an instant silent alarm regardless of the armed state of the control panel. It will display on the keypad. '11' KEYSWITCH ZONE - This zone type will arm and disarm the partition or partitions of the control panel that it resides in each time the zone is shorted. Keyswitch arming will report as user #99. '12' INTERIOR FOLLOWER WITH 'CROSS ZONE' ENABLED - This zone will be instant when the system is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times.
- THIS MANUAL IS FURNISHED TO HELP YOU UNDERSTAND YOUR SECURITY. SYSTEM AND BECOME PROFICIENT IN ITS OPERATION. ALL USERS OF.
- Installation Manuals for NX and any other security system used by Australian Security. NX-8 Install Manual. NX-216 Zone Expander Installation Manual.
If a 'Cross Zone' is not being timed it will start a 'Cross Zone' timer. If a 'Cross Zone' is being timed it will create an instant alarm. This zone will automatically bypass when enabled in Segment 1 of Location 23. '13' INSTANT ENTRY GUARD - This zone creates an instant alarm whenever it is tripped and the Stay LED is off. It will start an entry delay time 2 if it is tripped and the system is armed and the Stay LED is on. '14' ENTRY/EXIT DELAY 1 WITH GROUP BYPASS ENABLED - A trip will start entry delay 1.
This zone will bypass when the 'Group Bypass' command is entered at the keypad. The lack of a trip during exit delay will enable the Automatic Bypass or Instant mode if so programmed.
Networx Nx 8e User Manual
'15' INTERIOR FOLLOWER WITH GROUP BYPASS ENABLED - This zone will be instant when the system is armed and no entry or exit delays are being timed. It is delayed during entry/exit delay times. This zone will bypass when the 'Group Bypass' command is entered at the keypad. This zone will automatically bypass if enabled in Segment 1 of Location 23.
'16' INSTANT WITH GROUP BYPASS ENABLED - This zone creates an instant alarm whenever it is tripped and the Armed LED is on. This zone will bypass when the 'Group Bypass' command is entered at the keypad. '17' ENTRY/EXIT DELAY 1 WITH TAMPER ENABLED- A trip will start entry delay 1. The lack of a trip during exit delay will enable the Automatic Bypass or Instant mode if so programmed. This zone type can be used to enable tamper on a wireless transmitter. '18' INTERIOR FOLLOWER WITH TAMPER AND AUTO-BYPASS ENABLED - This zone will be instant when the system is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times.
This zone will automatically bypass if enabled in Segment 1 of Location 23. This zone type can be used to enable tamper on a wireless transmitter. '19' INSTANT WITH TAMPER ENABLED - This zone creates an instant alarm whenever it is tripped and the Armed LED is on.
This zone type can be used to enable tamper on a wireless transmitter. '20' ENTRY/EXIT DELAY 2 WITH TAMPER ENABLED-A trip will start entry delay 2. The lack of a trip during exit delay will enable the Automatic Bypass or Instant mode if so programmed. This zone type can be used to enable tamper on a wireless transmitter.
To perform a cellular test on a press.44 while the system is disarmed (Make sure that panel’s Location is 37, Segment is 2 and Bit is set to 7 if these settings are not inputted the.44 cell test will not work correctly.) Note: if Location 37, Segment 2, Bit 6 is set, performing the phone test will trigger the local siren. To avoid triggering the siren when performing the phone test, make sure Bit 6 is OFF. The NX-8 panel will not show any indication that the cell test has been sent.
To monitor if it has sent you can check the cell radio status on its LEDs L3 and L4: L4 should be blinking on for 2 seconds and off for 2 seconds L3 will blink once briefly as soon as you press.44 If the system is reporting to an alarm monitoring company, wait for a minute than check with the central alarm monitoring station to see if the cellular test signal was received correctly. The cellular test is also used by Alarm.com to set the module's parameters the first time the module is powered up. It ensures that Alarm.com will receive the sensors list and any other information required for proper signaling.Note: You can only do the cell test 6 times in a 24 hour period.
Caddx Nx-8 Manual Pdf
After that you, you’ll need to power-cycle the module if you want to do more phone tests, or you’ll need to wait a day. The GE NX-8 security system is compatible with Alarm.com NX-592E cellular communicators. Before trying to send alarm signals to your alarm monitoring company, the cellular radio must first be registered before performing a cellular communicator signal strength test.
If you are looking to reduce your monthly alarm monitoring rates for your home or business make sure to contact Geoarm Security at 1-877-443-6276 for your free consultation!.We are usually able to takeover just about any kind of security system, so don’t hesitate. GE NX-8 Product Manuals.