Owners Manual For Lennox Oil Furnaces
For review only, if you need complete ebook Lennox Furnace Service Manual. Oil furnaces replacement repair and service costs oil furnace installation cost.
GlobalPhotoGroup / Shutterstock.com Though should repair most furnace problems, you can take care of a few furnace repair tasks yourself. Is your furnace not working? If your heater doesn’t heat or works poorly, this guide will help you troubleshoot and fix typical problems. Need furnace help NOW?
If your home is heated with a, a furnace or a heat pump is at the heart of it. Here we look at how to handle furnace problems from a furnace working poorly to a furnace not working at all. For heat pump problems, see.
Though forced-air furnaces are normally quite reliable, they can break down. To avoid break downs, it pays to know how to take care of your furnace and fix it when something goes wrong. Inevitably, a furnace stops working when you need it most. Consequently, fixing becomes urgent very quickly. The following instructions will help. With a little do-it-yourself experience and the proper guidance, you can troubleshoot and repair a variety of furnace problems yourself.
General Furnace Maintenance For starters, once a year, vacuum out the area around the furnace’s blower. If possible, also slide out the fan unit, clean each fan blade with a toothbrush, and then vacuum with a brush attachment on a vacuum cleaner. While you’re at it, look for oil ports on the motor, normally located near the motor shaft. If the motor has these, apply two to three drops of non-detergent motor oil into each port (you may have to remove a cover plate to do this).
Though most contemporary motors don’t require lubrication, do lubricate motors with oil ports once a year. For more about maintenance, see.
©Don Vandervort, HomeTips To shut off the gas supply to your home, turn the valve until it rests perpendicular to the supply pipe (here the gas is on). Turn off the gas supply valve, typically located by your gas meter on the gas inlet pipe. Turn off the gas by rotating the valve one quarter turn with an.
When the gas is off, the valve’s oblong stem points perpendicular to the inlet pipe. Then call your gas utility or the fire department from a remote location. Do not return to your home until you know it is safe.
Furnace Not Working—No Gas Flame Older gas and combustion-fuel furnaces have pilot lights, whereas some newer ones have electronic ignition. Furnace with a Pilot Light If your older furnace utilizes a pilot light that won’t stay lit, the may be loose or faulty, the pilot orifice may be clogged, the pilot’s flame may be set too low, or the safety cutoff valve may be defective. The thermocouple is a copper rod that the pilot flame heats-up. When it gets hot enough, the thermocouple signals that there is enough heat to burn the gas fuel being released into the appliance—and so it allows the gas to be released to the burners.
In some cases where the pilot light won’t stay lit, the thermocouple needs to be adjusted or replaced. This is generally a job for a professional. Electronic Ignition Furnace On an electronic-ignition furnace, turn down the or turn the power switch off and then on again to reset the ignition control module. Listen for the sound of the spark or watch for the hot surface ignitor to glow (see your owner’s manual).
Next check and clean the furnace’s flame sensor. The video below shows you how—note that this guy fixes it in about 5 minutes. We would probably use a little bit of emory paper, but he cleans the sensor with a 5-dollar bill. Another video further down the page under the discussion of “ If your furnace keeps shutting off after about 5 minutes” shows the same project with a different brand of furnace. If your furnace has a pilot light, look for the flame. Check your owner’s manual or the instructions posted inside the furnace cabinet for step-by-step lighting instructions.
Usually this involves first turning the gas valve to Off and waiting a couple of minutes. Then you turn it to Pilot. Next, press and hold it down while you light the flame. Last, wait a minute or so, release it, and then turn it to On. If the furnace won’t light or ignites but fails again, call a Heating or Cycling Problems If your furnace runs and provides some heat but not enough 1Be sure nothing is blocking the flow of warm air.
2Be sure the thermostat is set properly to “Heat” and the fan is set to “On” or “Auto.” Then try raising the set temperature 5 degrees and waiting a few minutes. 3Be sure the room heating registers are open. 4Check the filter. Because a dirty filter can reduce efficiency, replace it with a if it’s dirty. 5Last, if these simple steps don’t work, have a check out your system because either the blower isn’t working properly or the system is out of balance.
Lennox Gas Fireplaces Manual
Need help NOW? If your furnace does not heat at all Thermostat malfunctions cause most heating system failures.
Other causes include a tripped circuit breaker or blown fuse, or—in the case of combustion furnaces—a pilot light that has gone out. If the heat doesn’t come on even when you adjust the thermostat above room temperature: 1Be sure the heater’s is set to Heat (if yours is a heating and cooling system). ©Don Vandervort, HomeTips If a circuit has tripped, reset it by turning it off and on. 2Be sure the furnace’s circuit breaker is on or that its fuse has not blown. Check both the main electrical panel and any secondary subpanels that supply power to the unit.
If the circuit has blown or tripped, reset the circuit breaker by flipping it all the way off and then on again. Or replace the fuse. If the circuit blows again, there is probably a short in the electrical system providing power to the furnace.
For this, you may need to call an electrical contractor. 3Be sure the furnace’s power switch is turned on.
Look for the switch next to or inside the furnace cabinet. If it isn’t on, turn it on, and wait for the furnace to engage. 4The motor may need to be reset because of an overload. Look for a Reset button near the blower motor’s housing and, if you find one, press it. If nothing happens, wait about 30 minutes for the motor to cool, and then try the Reset button again. 5Turn off the power to the furnace at the main electrical panel or subpanel.
Look for a fuse in the power switch. If one exists, see if it has blown.
Replace the fuse (be sure to follow the instructions in your owner’s manual). If you don’t have an owner’s manual or are unclear about what it will take to do this,. 6With a gas furnace, the pilot light may have gone out or the gas valve may be shut off. Check the furnace’s ignition. 7If the furnace still doesn’t work, be sure the thermostat isn’t faulty.
If your furnace cycles on and off too often The problem is often with the thermostat—especially if you have a combustion furnace. For information on how to solve and repair this problem, see. If your has a small lever that moves along a calibrated scale that indicates “longer” (not the heat temperature lever), you can try adjusting this—the heat anticipator. Just set it one calibration mark closer to the “longer” setting if the furnace goes off and on too frequently or one mark away if the furnace allows room temperature to rise too high or drop too low before going on or off.
It may take several hours for the thermostat to stabilize at this setting, so wait a while and then adjust it again if necessary. If making these adjustments doesn’t solve the problem, consider replacing your thermostat. When an electric-resistance furnace or heat pump turns off and on too frequently, the problem may be that the unit is overheating because of a clogged filter or a blower that is malfunctioning. First try cleaning. If none of these measures do the trick, call a furnace repair technician. If your furnace keeps shutting off after about 5 minutes This often indicates a problem with a faulty or dirty flame sensor. The video here shows how to deal with this problem.
Furnace Does Not Blow Air If your furnace’s motor runs but the blower doesn’t move air, the belt that connects the two probably has broken. Replacing it is an easy fix.
First, turn off all power to the unit and turn off the gas at the gas valve that serves the furnace. Remove the door on the front of the furnace cabinet to give you access to the blower (it might be on a slide-out drawer.) Check the number stamped on the belt and get an exact replacement from a home center or heating supply outlet.
©Don Vandervort, HomeTips Replacing a blower pulley is an easy fix. You can usually slip the belt on the motor’s (smaller) pulley first and then start it on the blower pulley. Rotate the blower pulley by hand, holding the belt in place but keeping your fingers from getting caught between the belt and the pulley. The belt should slip right into place. If it seems to be too tight or difficult to set in place, it may be necessary to adjust the motor mount to provide more slack. Then you can re-tighten the tension once the belt is in place.
Check the manufacturer’s specifications for proper tension—in most cases, the belt should deflect about an inch when you press down on it. Finally, some fan motors and fans need oiling; some have sealed bearings.
If recommended by your maintenance manual, oil the bearings according to the manufacturer’s directions. Blower Runs Continuously Two things can cause a blower to run continuously: the room thermostat or the limit switch located on the furnace just below the plenum (the box that distributes heated air to all the ducts). The limit switch shuts off the furnace if the air in the plenum gets too hot. Check the thermostat to see if the Fan switch has been turned on. If it has, turn it to Off or to Auto. If it is set to Off or Auto, the furnace’s limit switch must be adjusted.
Call a to adjust the limit switch, or follow the instructions in your owner’s manual to reset the pointers on the fan side of the limit control. Typically, the lower pointer should be set to about 90 degrees F., and the upper one should be at about 115 degrees F. Noisy Furnace or Duct Work Many heating ducts are metal, so they conduct noise quite readily from the air-handling unit to your rooms.
To break the conduction of sound, you can have a heating contractor insert flexible insulation duct work between the furnace or air conditioner and the duct work runs. Pinging or Popping Sounds A pinging or popping sound coming from the duct work can come from thermal expansion—the ductwork expanding and contracting as it heats and cools. Or, air blowing past a loose flap of metal can make the sound. Track along the duct runs, listening for the sound. If you locate it, make a small dent in the sheet metal to provide a more rigid surface that’s less likely to move as it heats and cools.
Rattling Noises If the furnace cabinet makes rattling noises when it runs, be sure the cover panels are screwed on tight. Tighten any loose panels. Squealing Noises Squealing sounds from a forced-air furnace generally occur when the belt that connects the motor to the fan slips. Tighten the fit by adjusting the motor mount.
Or, the belt is improperly aligned or worn and needs replacement. Follow the instructions in your owner’s manual. This job involves removing the access panel, loosening a couple of bolts that hold the blower motor at the proper tension, and adjusting its distance or realigning the belt. In many cases, it’s a good idea to remove the belt and buy a replacement at a home center. Last, when reinstalling the belt, be careful not to over-tighten it; this can wear out the motor bearings.
Grinding Sounds If the blower is making a grinding noise, shut off the unit and call a; the motor’s bearings are probably shot. Furnace Not Working—Oil Burner First of all, if the oil burner goes on and off too much, clean. If your oil burner doesn’t work at all, check to see if it is receiving electrical power, if the thermostat is broken or turned off, or if a flame sensor in the burner or heat sensor in the stack has signaled the unit to shut off. In the event that replacing the filter or checking these issues don’t solve the problem, call a furnace repair technician because oil-burning furnaces are complex to repair.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website. Manuals, parts lists, wiring diagrams for HVAC equipment: Free downloadable manuals for Air Conditioners, Boilers, Furnaces, Heat Pumps.
Here we provide free downloadable copies of installation and service manuals for heating, heat pump, and air conditioning equipment, or contact information for the manufacturers who can provide that information for nearly all major brands of HVAC equipment. We include links to contact information for each manufacturer or producer of these air conditioners, heat pumps, furnaces, boilers and related equipment, parts, and installation, repair, wiring diagrams, manuals. We include immediate downloads of example installation & repair manuals and wiring diagrams for air conditioners, heat pumps, and heating equipment from a variety of manufacturers as well as contact information to obtain the exact manual or wiring diagram for your unit. We also provide a to this topic, or you can try the page top or bottom as a quick way to find information you need.
is a licensed home inspector, past chapter president of the Hudson Valley chapter of the American Society of Home Inspectors, an educator, and building failures researcher in Kingston, NY who can be reached at or at 845-339-7984. Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair.
Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the. Also see our. 120 Carlton Street Suite 407, Toronto ON M5A 4K2.
Tel: (416) 964-9415 1-800-268-7070 Email:. The firm provides professional & &. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
Thanks to Alan Carson and Bob Dunlop, for permission for InspectAPedia to use text excerpts from The Home Reference Book & illustrations from The Illustrated Home. Carson Dunlop Associates' provides extensive home inspection education and report writing material.
illustrates construction details and building components, a reference for owners & inspectors. Special Offer: For a 5% discount on any number of copies of the Illustrated Home purchased as a single order Enter INSPECTAILL in the order payment page 'Promo/Redemption' space. to manufacturer's model and serial number information for heating and cooling equipment, useful for determining the age of heating boilers, furnaces, water heaters is provided by Toronto - Carson Dunlop Weldon & Associates Special Offer: Carson Dunlop Associates offers InspectAPedia readers in the U.S.A. A 5% discount on any number of copies of the Technical Reference Guide purchased as a single order. Just enter INSPECTATRG in the order payment page 'Promo/Redemption' space., Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume.
Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page 'Promo/Redemption' space. InspectAPedia.com editor Daniel Friedman is a contributing author. Or choose the for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones.
Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page 'Promo/Redemption' space. Building inspection education & report writing systems from. protocol ASTM Standard E 2018-08 for Property Condition Assessments. including home study & live classes at eleven colleges & universities. ASHI@Home Training 10-course program. Special Offer: Carson Dunlop Associates offers InspectAPedia readers in the U.S.A.
A 5% discount on these courses: Enter INSPECTAHITP in the order payment page 'Promo/Redemption' space. InspectAPedia.com editor Daniel Friedman is a contributing author. manages business operations,scheduling, & inspection report writing using Carson Dunlop's knowledge base & color images. The Horizon system runs on always-available cloud-based software for office computers, laptops, tablets, iPad, Android, & other smartphones.